LY3310-4 0.02% Three Phase Meter Test Bench

Introduction

LY3310-4 0.02% high accuracy three phase meter test bench with Isolated CT for measurement test centers, utilities, national Institute of metrology, meter manufacturers, and for R&D.

The number of test positions is flexible. The photo shows a configuration with 4 positions. 

ItemValues
Reference StandardClass 0.02
Voltage range57.7V,100 V,220 V,380V
Current range0.01A,0.025A,0.05A,0.1A,0.25A,1A,2.5A, 5A,10A,25A,50A,100A
Voltage output capacity3×500 VA per phase
Current output capacity3×2000 VA per phase
Voltage-and current adjustmen0%-120%×Range,minimum voltage 30V
Phase shift±180°
Test frequency40 Hz-70 Hz
Power stability≤0.02%/120 s
Distortion≤0.5%
HarmonicsUp to 51
Harmonics amplitude≤40%
Hammonics phase shift0°-360°
Pulse outputMax.50 kHz
Pulse inputMax.10 kHz
PositionsClass 0.02,quick connectors and ICTs, close link
StructureReference standard and source integrated in rack
Operating power source3×220 V/380V±15%,45 Hz-65 Hz(other voltages or frequencies on request)
Operating temperature23℃±10℃
Humidity≤85%